Accuracy : ±0.5% initial pulse response for all models. Specifications for transformer ratio, accuracy, and droop are at open circuit. Rise time and bandwidth are when terminated with 50 ohms. All models are electrostatically shielded and have a 50 ohm output impedance.

Other standard and custom models available.
1 - 7 of 7 | Results Per Page | View | Unit of Measure
1 

Item #

Output
(Accuracy ±0.5%)

Inner
Diameter

Max. Current
(Peak)

Max. Current
(RMS)

Approx. 3dB
Point Low

Sort by
N/A 0.1 (volt/amp) N/A 0.5 in N/A 5 k A N/A 50 A N/A 1 Hz
N/A 0.1 (volt/amp) N/A 0.5 in N/A 5 k A N/A 50 A N/A 100 Hz
N/A 0.1 (volt/amp) N/A 2 in N/A 5 k A N/A 65 A N/A 1 Hz
N/A 0.1 (volt/amp) N/A 2 in N/A 10 k A N/A 65 A N/A 1 Hz
N/A 0.5 (volt/amp) N/A 2 in N/A 1 k A N/A 15 A N/A 40 Hz
N/A 1 (volt/amp) N/A 0.5 in N/A 500 A N/A 5 A N/A 140 Hz
N/A 1 (volt/amp) N/A 2 in N/A 500 A N/A 7.5 A N/A 125 Hz
1 - 7 of 7 | Results Per Page | View | Unit of Measure
1